ONT Ontario International Airport PAMS Site Surface Data Notes Data reporting started: September 20, 2007 Data collection has been on-going at this site for some time but the processing and posting of the data here begins on the above date. Shortly after inception to the present -- The temperature/relative humidity aspirator blower failed and has been inoperable. Data should be used with care as it will be subject to solar radiation effects. Sonic wind data at this site are from a 2-D instrument. This particular instrument has known issues with periodic spikes in the wind speed data that affects both the calculated wind speed and wind direction data. Audits performed have shown the data to be accurate when the spikes are not present. However, it is not always apparent when the data may have been affected. This sensor was removed during the audit on June 3, 2009. May 3, 2011 -- The 2011 data file now includes the last field for the aspirator current. In the months prior to the data logger program uploading an empty field will be in the file (only a comma). During the installation month the values for aspirator current will appear. The aspirator current started recording on March 29, 2011. May 13, 2013 -- The UV sensor failed and was flagged as instrument failure until such time that a replacement is available and is installed.